3 Electrical considerations
3.1 Forward voltage as a function of temperature
Case temperature t
c
[°C]
98.5
99.0
99.5
100.0
101.0
100.5
101.5
020406080100120
98.0
3.2 Electronic control gear/LED module combination
PrevaLED
®
Core Z3 LED modules can either be used with
constant-current control gears or in combination with
OSRAM OTi control gears. The OTi control gears provide a
thermal shutdown function as well as an automatic fl ux cali-
bration. Constant- current control gears do not provide these
features. The table below shows possible combinations of
PrevaLED
®
Core Z3 LED modules and OSRAM ECGs.
Modules Drivers
Typ. current
[mA]
OT 35/45
LTCS
OT 45
DALI LTCS
OTe
25/CS
OTe
35/CS
OTe
50/CS
OTe 50/CS
FAN
OT FIT
15/CS
OT FIT
25/CS
OT FIT
35/CS
OTi DALI
25
OTi DALI
35
OTi DALI
50 FAN
PL-CORE-1100-830 235
1160
PL-CORE-1100-840 220 1210
PL-CORE-2000-830 400 2070
PL-CORE-2000-840 385 2160
PL-CORE-2000-930 490 1750 TBD
PL-CORE-3000-830 590 3035
PL-CORE-3000-840 575 3115
PL-CORE-3000-930 730 2900 2900 2900 3240 2900
PL-CORE-5000-830 950 3400 3400 TBD
PL-CORE-5000-840 885 3700 3700 TBD
PL-CORE-5000-930 1155
4600 4600
2300: System fi t OK nominatyp. fl ux level (lm) if deviating from nominal
: System fit OK for 1 or more current settings
Preliminary data. The fl ux levels realized with fi xed-value constant-current OTe and OT FIT drivers will change as the effi cacy of the modules evolves.
110 0 l m 2000 lm 3000 lm 5000 lm